Display units

Every number OpenFlowsheet stores, hashes or computes with is in SI. A reader may ask for some numbers in other units — degrees Celsius, bar, kW, kmol/h — and gets them beside the SI values, never instead of them. The SI value stays in the document and is the one to compute with; the display value is for reading (ADR 0075).

Asking for display units

Two operations take the optional request member display_units: get_stream_table (the stream table and energy summary) and get_job_result (the explanation of a failed run). The value is a comma-separated list: a preset first, then kind=unit items, each overriding the preset for its kind.

Transport Example
Python app.get_stream_table(job_id, display_units="eng")
CLI openflowsheet streams --project DIR --job JOB --display-units "eng,pressure=barg"
HTTP GET /v1/jobs/{job_id}/stream-table?display_units=eng (percent-encoded)
MCP the tool argument display_units of get_stream_table and get_job_result
Web shell the units control in the header (SI, eng, eng with gauge pressure)

A converted number gains a display item, {"value": 25.0, "unit": "degC"}; the response's root echoes the preference as display_units: {units, ambient_pressure}. A display value that is not a finite number is null with the reason display_out_of_range. A malformed preference is refused invalid_request (display_units_invalid); a unit the table does not have is refused unsupported (display_unit_unsupported). Without display_units every response is exactly what it was before display units existed.

Text written for people spells the temperature units with the degree sign: message text reads 25.00 °C, the CLI's text table labels the row T [°C] and the web shell heads the column T (°C) (°F likewise). Everything a program reads keeps degC and degF: the display item's unit, the display_units echo (and the CLI's display units: header line, which repeats it), CSV column names (T_degC) and every request — °C is not accepted as input.

Presets

Preset Units
si none: SI throughout (the response still echoes the preference)
eng temperature=degC, temperature_difference=degC, pressure=bar, molar_flow=kmol/h, mass_flow=kg/h, heat_rate=kW, power=kW, enthalpy_flow=kW, molar_enthalpy=kJ/mol, specific_enthalpy=kJ/kg, specific_entropy=kJ/(kg K)

Output units

SI = a·u + b, with a and b exact. A number converts by its declared kind, never by its unit symbol: temperature=degC never touches a temperature difference, and heat_rate, power and enthalpy_flow are three kinds although all are watts. The SI unit of each kind is the identity and is not listed.

Kind Unit a b Direction
temperature degC 1 5463/20 input and output
temperature degF 5/9 45967/180 input and output
temperature_difference degC 1 0 input and output
temperature_difference degF 5/9 0 input and output
pressure kPa 1000 0 input and output
pressure MPa 1000000 0 input and output
pressure bar 100000 0 input and output
pressure atm 101325 0 input and output
pressure psi 8896443230521/1290320000 0 input and output
pressure barg 100000 ambient (declared) output
pressure psig 8896443230521/1290320000 ambient (declared) output
molar_flow kmol/s 1000 0 input and output
molar_flow mmol/s 1/1000 0 input and output
molar_flow mol/h 1/3600 0 input and output
molar_flow kmol/h 5/18 0 input and output
mass_flow g/s 1/1000 0 output
mass_flow kg/h 1/3600 0 output
heat_rate kW 1000 0 input and output
heat_rate MW 1000000 0 input and output
power kW 1000 0 input and output
power MW 1000000 0 input and output
enthalpy_flow kW 1000 0 output
enthalpy_flow MW 1000000 0 output
molar_enthalpy kJ/mol 1000 0 output
specific_enthalpy kJ/kg 1000 0 output
molar_entropy kJ/(mol K) 1000 0 output
specific_entropy kJ/(kg K) 1000 0 output
dimensionless % 1/100 0 input and output
mole_fraction % 1/100 0 input and output
mass_fraction % 1/100 0 output

Gauge pressure and the ambient pressure

barg and psig are display units only: p_gauge = p_absolute − p_ambient, with the ambient pressure the project declares. It is never assumed — a gauge unit in a project without a declared ambient is refused invalid_request (ambient_pressure_undeclared). An operator declares it:

openflowsheet project ambient --project DIR --pressure 1.01325 --unit bar
openflowsheet project ambient --project DIR --clear

The value is converted to Pa (Pa, kPa, MPa, bar, atm or psi; a gauge unit is refused), stored in project-policy.json as ambient_pressure and audited as project_ambient. get_project reports it. It belongs to no revision, run, bundle, certificate, cache key or replay: two projects that differ only in their ambient produce byte-identical runs. Declaring it changes the project policy's policy_sha256, which jobs record as provenance.

Input units

Inputs are unchanged by display units (ADR 0016): a revision or a change may give a quantity in these units, converted to SI when it is validated. Gauge pressures are not accepted as inputs (L-X04-1).

Kind Units accepted besides SI
temperature, temperature_difference degC, degF
pressure kPa, MPa, bar, atm, psi
heat_rate, power kW, MW
molar_flow kmol/s, mmol/s, mol/h, kmol/h; and the mass-basis kg/s, g/s, kg/h
dimensionless, mole_fraction % (fractions only)

What stays SI

  • Every stored or hashed document: revisions, bundles and every bundle member, artifacts, validation reports, job documents and the audit log (L-X04-2).
  • Inside a converted response, the SI members themselves, the stream table's check quotes (checks[].value, tolerance: verification evidence), and run-failure params.
  • The web shell's as-solved state table on the streams screen (L-X04-2).
  • Every number without a display kind or row: the stream table's S_flow, V_flow, rho, v and molar_mass, and message numbers without a quantity kind (L-X04-3).

A display value is never an input to anything: no run, cache key, certificate, label, replay or comparison reads one, and no request that starts or changes work accepts display_units.